h2.Code 5083: «lamp cathode fan — speed low» (Warning)
| Situation | Solution | |
| Blocked Cathode Fan (reference 2 image). | Check if the Cathode Fan is not blocked. Ensure that the Cathode Fan can turn freely. | |
| Damaged wire unit (reference 1 & 5 image) of the Cathode Fan. | Check if the wire unit of the Cathode Fan is not damaged. Repair if possible, otherwise replace with new one. | |
| Malfunction Fan Control board. | Replace the Fan Control board. See service manual chapter «Replacement of a Card Cage board». | |
| Cathode fan (reference 1 image) end of life. | Replace the Cathode Fan. See service manual chapter «Replacement of the Cathode fan». | |