Why Does My Dolby DSS220 Server Show Transport Not Available After Each Boot?

Dec 17, 2020•Knowledge

Question

This article applies to: DSS220/CAT745

Why does my DSS220 Show «Transport Not Available» and «Updating» after each boot?

Answer

On boot up, a DSS220 may show «Transport Not Available» and «Updating» for approximately five minutes each time the unit is started up.

After the upgrade has reached 100%, playback is then possible.

This can be caused by a HDMI Board issue, either an issue with the firmware or a failure of the hardware itself on the HDMI daughter board. HDMI playback will not be possible with this issue, which can be verified by downloading a set of logs from the Server and uploading them to http://loganalyzer.dolbycustomer.com/ where it may list «HDMI Board Failure — A software upgrade has not written the HDMI Software successfully».

This is sometimes recoverable by repeating the firmware flash procedure a number of times: To do this, hold down the reset (RST) button on the faceplate of the CAT745 IMB for 3 seconds until the RDY LED goes out. The CAT745 will reset and re-load its firmware. Once the firmware version is reported to the DSS220, the software will automatically force the re-flash of the IMB if the HDMI firmware version does not match the required version. It may require multiple attempts to re-flash the HDMI firmware, make sure not to exceed 5 attempts. If the DSS220 no longer forces another update after a reboot, then the firmware has successfully been updated.

Following this, if you require further support, please contact the Dolby Cinema Support Team.

—

Contact us: How do I Contact Dolby Cinema Support?