h2.Code 5082: «lamp cathode fan — speed too low» (Error)
| Situation | Solution | |
| Wire unit (reference 1image) of the Cathode Fan is disconnected. | Remove the left side cover of the projector and check the connection of the Cathode Fan. | |
| Wire unit (reference 5 image) of the fan units is disconnected from the Signal Backplane. | Remove the front cover and front dust filter from the projector and check if the wire unit (reference 5image) is inserted in the Signal Backplane. | |
| Blocked Cathode Fan (reference 2 image). | Check if the Cathode Fan is not blocked. Ensure that the Cathode Fan can turn freely. | |
| Damaged wire unit. | Check if the wire unit of the Cathode Fan is not damaged. Repair if possible, otherwise replace with new one. | |
| Malfunction Fan Control board. | Replace the Fan Control board. See service manual chapter «Replacement of a Card Cage board». | |
| Cathode fan (reference 1 image) end of life. | Replace the Cathode Fan. See service manual chapter «Replacement of the Cathode fan». | |
| worddavf7642a8fdc55b86da4bc538a5c6ad146.png | ||