h2.Code 5005: «lamp power supplies — communication failed» (Error)
| Situation | Solution | |
| LPS communication cable disconnected from the CTLB-IN port of the first LPS unit in the LPS rack. | Check if the LPS communication cable (reference 4 of image) is connected with the CTLB-IN port of the first LPS unit in the LPS rack of the projector. | |
| Disconnected blue LPS cascade wire unit (CTLB-IN / CTLB-OUT). | Reconnect the blue wire unit (reference 5 image) between the «CTLB-IN» and «CTLB-OUT» sockets of the LPS units. | |
| LPS communication cable disconnected form the Signal Backplane. | Check if the LPS communication cable (reference 7 of image) is connected with the Signal Backplane. | |
| Malfunction of one of the LPS modules. The red LED «ERR» of the malfunction LPS module lit up (reference 8 of image). | Replace the malfunction LPS unit. See service manual chapter «Removal of an LPS module». | |
| Malfunction Barco Cinema Controller board. | Replace the malfunction Barco Cinema Controller board. See service manual chapter «Replacement of a Card Cage board». | |
| worddav2800800847934e4b77331e71c5d9b3b2.png | ||
| worddav3710d198aa4c24996b5f05695ca5360d.png | ||